Food code section 47 — the 2nd most-cited section of Chicago's food code over the last year.
Food & non-food contact surfaces cleanable, properly designed, constructed & used
Observed table attached can opener with build up of food grime. Instructed to detail clean and maintain.
Food & non-food contact surfaces cleanable, properly designed, constructed & used
Observed plastic white protective coating on tables and equipment. Instructed person in charge to remove and maintain surfaces smooth and easily cleanable.
Food properly labeled; original container
Observd bulk items (flour) in non-original containers not labeled. Instructed person in charge to label all bulk items and maintain.
Toilet facilities: properly constructed, supplied, & cleaned
Observed toilet fixtures in rear staff restroom to be soiled. Instructed person in charge to clean and maintain.
Physical facilities installed, maintained & clean
Observed large hole in wall in rear storage area behind large mixer. Instructed to close hole and maintain area smooth and easily cleanable.
Allergen training as required
Observed no allergen certificate on site for certified manager. Instructed person in charge to obtain allergen training and retain on site.
Section numbers moved in 2018. Chicago renumbered its food code that July, so the same section number means something different in older inspections. Everything on this page is drawn from the last year only.
Food & non-food contact surfaces cleanable, properly designed, constructed & used
4-101.19: observed rust on lower shelf of prep table in first floor rear prep area near exit door. Instructed to remove rust or replace prep table, instructed nonfood contact surfaces of equipment shall be constructed of a corrosion resistant, nonabsorbent and smooth material for ease of cleanability. Observed containers and boxes stored on floor in basement dry storage area. Instructed to provide adequate shelving units to elevate all food and non food items at least six inches off of floor for ease of cleanability.
Food & non-food contact surfaces cleanable, properly designed, constructed & used
4-202.15: observed rust on can opener on prep table in first floor rear prep area near exit door. Instructed to remove rust or replace can opener, instructed food contact surfaces of equipment shall be constructed of a corrosion resistant, nonabsorbent and smooth material for ease of cleanability.
Insects, rodents, & animals not present
6-202.15: observed openings at base of front entrance outer door. Instructed to seal all outer openings to prevent pest entrance.
Contamination prevented during food preparation, storage & display
3-307.11: observed no left splash guard on handwashing sink in beverage station. Instructed to install left splash guard on handwashing sink in beverage station to prevent contamination of prep surfaces and equipment to the left of handwashing sink. Observed no right splash guard on handwashing sink in bar. Instructed to install right splash guard on handwashing sink in bar to prevent contamination of prep surfaces and equipment to the right of handwashing sink.
Physical facilities installed, maintained & clean
6-501.11: observed chipping wall and ceiling in basement dry storage area. Instructed to remove chipping wall and ceiling, smoothly repair and repaint in said area for ease of cleanability.
Adequate ventilation & lighting; designated areas used
6-303.11: observed missing light bulbs or non working lights in all hoods in facility. Instructed to replace all missing light bulbs and repair all non working lights in hoods in facility and maintain.
Allergen training as required
2-102.13: at time of inspection facility provided no allergen awareness training certificate for one employee with city of Chicago food service sanitation certificate. Instructed to provide valid proof of allergen awareness training for all employees with city of Chicago food service sanitation certificates.
Food & non-food contact surfaces cleanable, properly designed, constructed & used
Observed cases, boxes and bags stored on soda crates or floor in rear dry storage area. Instructed to provide adequate shelving units to elevate all food and non food items at least six inches off of floor for ease of cleanability.
All food employees have food handler training
At time of inspection facility provided no food handler training certificates for multiple food handlers. Instructed to provide valid food handler certificates for all food handlers.
Food & non-food contact surfaces cleanable, properly designed, constructed & used
4-101.19: observed rust on shelving unit in first floor rear prep/dishwashing area. Instructed to remove rust or replace shelving unit, instructed nonfood contact surfaces of equipment shall be constructed of a corrosion resistant, nonabsorbent and smooth material for ease of cleanability.
Food & non-food contact surfaces cleanable, properly designed, constructed & used
4-501.11: observed damaged gasket on right door of small two door cold holding unit across from cookline in first floor prep area. Instructed to replace damaged gasket on said cold holding unit and maintain
Insects, rodents, & animals not present
6-202.15: observed opening at base of outer front entrance door and left side of rear exit door. Instructed to seal all outer openings to prevent pest entrance.
Contamination prevented during food preparation, storage & display
3-307.11: observed paper towel dispenser for handwashing sink in front prep area installed above knife rack. Instructed to relocate and reinstall paper towel dispenser so that it shall not contaminate knives in knife rack.
Plumbing installed; proper backflow devices
5-205.15: observed leaking faucet at handwashing sink and three compartment sink in first floor rear prep/dishwashing area. Instructed to repair and maintain.
Adequate ventilation & lighting; designated areas used
6-303.11: observed no light bulbs in hood in rear prep/dishwashing area. Instructed to install light bulbs in hood in rear prep/dishwashing area to increase light intensity.
All food employees have food handler training
2-102.13: at time of inspection facility provided expired or no food handler training certificates for food handlers. Instructed to provide valid food handler certificates for all food handlers.
Allergen training as required
2-102.13: at time of inspection facility provided expired or no allergen awareness training certificates for employees with city of Chicago food service sanitation certificates. Instructed to provide valid proof of allergen awareness training for all employees with city of Chicago food service sanitation certificates.
Food & non-food contact surfaces cleanable, properly designed, constructed & used
Found the large can opener on the prep table in the kitchen with a build up of dirt and food. Instructed to clean and maintain can opener.
Adequate handwashing sinks properly supplied and accessible
Found no hand washing signs at the prep and staff's toilet rooms. Instructed to provide signs and maintain.
Adequate handwashing sinks properly supplied and accessible
Found the faucet on the washbowl in the women staff's toilet room by the playground leaking at the base. Instructed to fix and maintain good plumbing.
Plumbing installed; proper backflow devices
Found the hot water pressure at the 3-compartment sink in the kitchen low. Instructed to increase pressure and maintain.
Physical facilities installed, maintained & clean
Found water-stained ceiling tiles in the classrooms and toilet rooms. Instructed to replace ceiling tiles. Maintain same.
Physical facilities installed, maintained & clean
Found the floors under the heavy equipment and sinks in the kitchen and storage with dirt and debris. Instructed to clean and maintain floors.
Food & non-food contact surfaces cleanable, properly designed, constructed & used
4-201.11: **c** equipment and utensils- durability and strength observed damaged gaskets at the 2-door tall refrigerator in main kitchen food prep area. Must reapir and maintain.
Compliance with variance/specialized process/HACCP
Observed facility not meeting compliance with variance/specialized process; facility in (rop) reduce oxygen packaging of cooked and raw meat, cheese, sauces etc in prep kitchen area. Informed person in charge of requirements and facility must meet and maintain. Unit not on-site pic indicated previous ownership took rop machine. Manager immediately and voluntarily disposed of 150 lbs of products worth $3500.00 through denaturing process priority violation 7-38-005 citation issued.
Variance obtained for specialized processing methods
Observed facility not meeting variance requirements for modified (rop) packaging performed in facility.no HACCP on site of documentation for procedure preformed in facility. Informed facility of requirements must meet and maintain. Citation consolidated with #29.
Insects, rodents, & animals not present
Observed evidence of rodent activity on the premises. Observed approximately 4 rat droppings in prep and over 500 rat dropping in basement water heater and unused equipment storage space. Management instructed to clean and remove all rodent droppings from all affected areas. Additional pest control service is needed to eliminate the pest activity. Pest control on-site installing bait boxes throughout. Priority foundation #7-38-020(a). Citation issued.
Personal cleanliness
Observed food handlers not wearing beard restraints. Instructed to wear at all times when preparing food.
Warewashing facilities: installed, maintained & used; test strips
Observed water backing up at the 3 compartment sink area. When water is released from 2nd sink basin, water backs up into 1st and 3rd sink basins. Instructed manager to repair before re-inspection date. Priority foundation violation #7-38-025. Citation issued.
Non-food/food contact surfaces clean
Observed grease buildup on cooking equipment, walls, surrounding floors and shelving units in the kitchen/prep areas. Instructed to degrease, clean and sanitize.
Garbage & refuse properly disposed; facilities maintained
Observed outside dumpster with lids not closed due to trash overflowing. Instructed to correct and maintain to ensure tight fitting lids. Priority foundation violation #7-38-020(b). Citation issued.
Physical facilities installed, maintained & clean
Noted dirty and dusty ceiling fans through out the premise. Instructed to clean and maintain. Also noted peeling paint on ceiling in rear prep area. Must paint ceiling. Observed dirt and food debris on walls behind all cooking equipment in main kitchen food prep area. Must clean. Observed missing wall tile in the employee small washroom must repair replace. Walls must be smooth and easily cleanable
Physical facilities installed, maintained & clean
Observed a few broken floor tiles in front pizza prep area. Must regrout floor throughout rear kitchen prep area. Observed a few water damaged ceiling tiles in rear food storage area. Must repair or replace
Adequate ventilation & lighting; designated areas used
Observed heavy grease and dust build up on ventilation hood and filetrs above cooking equipment. Must clean and maintain.
All food employees have food handler training
Must provide proof of training or food handler certificates for all required employees.
Allergen training as required
Observed no certified food manager with allergen training. Instructed any persons with the city of Chicago food sanitation certificate to comply with completion of training. Must provide documentation.
Food & non-food contact surfaces cleanable, properly designed, constructed & used
Found the large can opener on the prep table in the prep area with food and dirt build up. Instructed to clean and maintain can opener.
Adequate handwashing sinks properly supplied and accessible
Found the middle handwashing sink has no signage. Instructed to provide signage and maintain.
Physical facilities installed, maintained & clean
Found the wall above the middle hand-washing sink cracked. Instructed to scrape and repaint wall to maintain a smooth and easily cleanable surface. -found water-stained ceiling tile/light shield in the rear toilet room. Instructed to replace all and maintain.
Food & non-food contact surfaces cleanable, properly designed, constructed & used
Observed gaskets on cold hold units in rear prep area where frozen foods are held to be damaged. Instructed person in charge to repair and maintain.
Proper cold holding temperatures
Observed tcs food ground beef in cold hold unit at 47f. Instructed person in charge that all cold held foods must be kept at 41f and below. Person in charge voluntarily discarded 5lbs of par cooked ground beef at cost of $50. Priority violation #7-38-005. Citation issued.
Food & non-food contact surfaces cleanable, properly designed, constructed & used
4-101.19: observed containers and boxes stored on crates throughout facility, in basement and in prep areas. Instructed to provide adequate shelving units to elevate all food and nonfood items at least six inches off of floor for ease of cleanability. Observed plastic film on two cold holding units in facility and observed aluminum foil table liner. Instructed to remove plastic film and aluminum foil liner, instructed nonfood surfaces of equipment shall be constructed of a corrosion resistant, nonabsorbent and smooth material.
Food & non-food contact surfaces cleanable, properly designed, constructed & used
4-501.11: observed damaged lid of chest freezer in basement. Instructed to repair or replace damaged lid of chest freezer in basement.
Food & non-food contact surfaces cleanable, properly designed, constructed & used
4-202.15: observed rust and food debris on can opener. Instructed to remove rust and clean and sanitize can opener.
Food-contact surfaces: cleaned & sanitized
4-602.11(b-e): observed black and orange moldlike substance on upper interior components of ice machine. Instructed to destroy ice, clean and sanitize interior components of ice machine to prevent contamination of ice.
Insects, rodents, & animals not present
6-202.15: observed opening at base of left front entrance door. Instructed to seal all outer openings to prevent pest entrance.
In-use utensils: properly stored
3-304.12: observed in use utensils(knife,tong and scoop) stored in container of water between uses in front prep area. Instructed during pauses in food preparation or dispensing utensils shall be stored on a clean portion of the food preparation table or cooking equipment only if the in use utensil and the food contact surface of the food preparation table or cooking equipment are cleaned and sanitized throughout the day at least every four hours.
Physical facilities installed, maintained & clean
6-501.11: observed stained ceiling in front prep area. Instructed to repair and smothly repaint stained ceiling for ease of cleanability and maintain.
Physical facilities installed, maintained & clean
6-501.114: observed boxes and pot stored outside of rear exit door of facility. Instructed to remove all unused or non working equipment that is unnecessary to the operation or maintenance of the establishment.
All food employees have food handler training
2-102.13: at time of inspection facility provided expired food handler training certificate for food handler. Instructed to provide valid food handler certificates for all food handlers.
Food & non-food contact surfaces cleanable, properly designed, constructed & used
Observed crates and boxes stored on floor in storage room outside of walk in cooler and in storage room outside of all gender employee washroom. Instructed to provide adequate shelving units to elevate all food and non food items at least six inches off of floor for ease of cleanability.
Food-contact surfaces: cleaned & sanitized
Observed low temperature dish machine improperly sanitizing at a concentration of 0ppm chlorine. Corrected on site 'held for inspection' tag placed on low temperature dish machine. Instructed once low temperature dish machine has been repaired and is sanitizing at a minimum concentration of 50ppm chlorine e-mail food@cityofchicago.org to request tag removal prior to using unit.( note: low temperature dish machine not in use at time of inspection, instructed facility must use the three compartment sink to sanitize all equipment and utensils. Priority violation 7-38-025 no citation issued
Insects, rodents, & animals not present
Observed over 60 mouse droppings in facility. Observed mouse droppings in areas such as dishwashing area, rear dry storage area near employee washroom, table near prep table and knife rack and rear storage room near dumpster exit. Instructed to eliminate rodent activity, remove mouse droppings and clean affected areas. Instructed licensed pest control company must service facility on or after 11/23/2026. Priority foundation violation 7-38-020(a) citation issued
Insects, rodents, & animals not present
Observed opening on left side of rear exit door leading to dumpster area. Instructed to seal all outer openings to prevent pest entrance.
Warewashing facilities: installed, maintained & used; test strips
Observed no data plate on low temperature dish machine. Instructed to provide an easily accessible and readable data plate affixed to the machine by the manufacturer that indicates the machine's design and operation specifications.
Plumbing installed; proper backflow devices
Observed low water pressure at rinse sink in dishwashing area. Instructed to increase water pressure at rinse sink in dishwashing area and maintain.
Toilet facilities: properly constructed, supplied, & cleaned
Observed no covered receptacle in all gender employee or women's washrooms. Instructed to provide covered receptacles in said washrooms for sanitary products
Physical facilities installed, maintained & clean
Observed stained and missing ceiling tiles in eastside small dry storage room near lockers. Instructed to replace all stained or missing ceiling tiles in facility and maintain
Physical facilities installed, maintained & clean
Observed unused hot holding unit stored on patio. Instructed to remove all unused or non working equipment that is unnecessary to the operation or maintenance of the establishment.
All food employees have food handler training
At time of inspection facility provided no food handler training certificates for any food handlers. Instructed to provide valid food handler certificates for all food handlers.
Food & non-food contact surfaces cleanable, properly designed, constructed & used
Using grocery bags to store food in chest freezer, instructed to use food grade for food storage.
Adequate handwashing sinks properly supplied and accessible
No hand soap provided to employees restroom hand wash sink. Instructed to provide.
Warewashing facilities: installed, maintained & used; test strips
No sink stoppers for 3-comp sink, instructed to obtain for proper washing and sanitizing.
Allergen training as required
No allergen training certificate for food service manager. Instructed to obtain.
Food & non-food contact surfaces cleanable, properly designed, constructed & used
4-501.11: observed damaged gasket on tall one door cold holding with glass door by rear exit. Observed damaged gaskets on both doors of small two door cold holding unit across from cookline next to handwashing sink in prep area. Instructed to replace damaged gaskets on said units and maintain. Observed damaged gaskets on both doors and missing interior panel on right door of small two door holding unit across from cookline. Instructed to replace and maintain.
Food & non-food contact surfaces cleanable, properly designed, constructed & used
4-101.13(c): observed ceramic/clay drinking cups on site. Instructed to ensure cups are lead-free or lead-safe levels and maintain documentation of such on-site or removal from premises.
Food-contact surfaces: cleaned & sanitized
4-602.11(b-e): observed black moldlike substance on upper interior components of ice machine. Instructed to destroy ice, clean and sanitize interior of ice machine to prevent contamination of ice.
Insects, rodents, & animals not present
6-202.15: observed opening at base of front entrance outer door. Instructed to seal all outer openings to prevent pest entrance
Physical facilities installed, maintained & clean
6-501.12: observed dusty ceiling tiles and ceiling vents in dishwashing area. Instructed to clean.
Physical facilities installed, maintained & clean
6-501.11: observed stained ceiling tiles in dishwashing area. Instructed to replace all stained ceiling tiles throughout facility
Physical facilities installed, maintained & clean
6-501.114: observed two unused sinks outside in rear of facility. Instructed to remove all unused or non working equipment that is unnecessary to the operation or maintenance of the establishment.
Food & non-food contact surfaces cleanable, properly designed, constructed & used
Found the storage racks inside the 2-door reach in cooler in the prep area rusty. Instructed to remove rust and maintain a smooth, easily cleanable and rust-free surface. -top surface of the washbowl in the rear women's toilet room needs to be recaulked. Instructed to recaulk and maintain.
Food & non-food contact surfaces cleanable, properly designed, constructed & used
Found the large can opener on the prep table with a build up of food and dirt. Instructed to clean and maintain large can opener.
Adequate handwashing sinks properly supplied and accessible
Found no handwashing signage at the washbowl in the rear women's toilet room. Instructed to provide signage and maintain.
Thermometers provided & accurate
Found no thermometer inside of the rear reach in cooler in the prep area. The outer thermometer on the walk in cooler in the basement does not work. Instructed to provide and conspicously place thermometers in coolers. Maintain same.
Insects, rodents, & animals not present
Found the front door with a 1/4" gap underneath on the right side of the door, making it not rodent/insect proofed. Instructed to rodent/insect proof door and maintain.
Plumbing installed; proper backflow devices
Found a leak at the base of the faucet on the 3-compartment sink in the prep area. Instructed to fix leak and maintain good plumbing.
Allergen training as required
Found the cfm on site has no food allergen training certificate. Instructed to obtain and maintain a valid food allergen training certificate.
Food & non-food contact surfaces cleanable, properly designed, constructed & used
4-101.19: observed containers stored on floor of prep/dishwashing area. Instructed to provide adequate shelving units to elevate all food and nonfood items at least six inches off of floor for ease of cleanability.
Food & non-food contact surfaces cleanable, properly designed, constructed & used
Observed dark grooves into the cutting boards. Must repair/replace and maintain
Thermometers provided & accurate
Must provide and maintain working thermometers inside coolers and freezers to monitor ambient air temp.
Insects, rodents, & animals not present
Observed the of the bottom of the front door in pair repair (worn). Must repair and maintain to prevent entry point for pests.
Plumbing installed; proper backflow devices
Observed 3 comp sink faucets in poor repair(noted 1 fauct taped up and the other with leaks). Must repair and maintain
Physical facilities installed, maintained & clean
Observed the floors inside the walk in cooler dirty. Also noted the ceiling tiles and air vent cover throught out dirty. Must clean and maintain
Physical facilities installed, maintained & clean
Observed the floor inside the walk in cooler in poor repair. Also noted the front door in poor repair. Must repair and maintain
Adequate ventilation & lighting; designated areas used
Must detail clean and maintain the filters and hood above the cooking equipment.
Allergen training as required
Observed the city certified manager on site allergen training certificate expired. Instructed to renew and maintain. Instructed manager that all city certified foodservice manager must comply.
Food & non-food contact surfaces cleanable, properly designed, constructed & used
Shelves in reach in cooler in prep area are rusty. Instructed to remove all rust and maintain
Management, food employee and conditional employee; knowledge, responsibilities and reporting
No employee health policy on site at time of inspection. Instructed person on site to have a signed policy for all employees. Priority foundation 7-38-010 no citation issued
Consumer advisory provided for raw/undercooked food
No consumer advisory on menu at time of inspection. Instructed manager to correct and maintin priority foundation 7-38-005 no citation issued
Proper cooling methods used; adequate equipment for temperature control
Reach in cooler in main prep area in need of repair. 49.8 degree air temp. Instructed manager to correct and maintain. Priority violation 7-38-005 no citation issued
Insects, rodents, & animals not present
No complete logbook on site at time of inspection instructed manager to obtain logbook and maintain at all times priority foundation 7-38-020(c) no citation issued
Plumbing installed; proper backflow devices
No mop sink on site. Instructed to install and maintain
Physical facilities installed, maintained & clean
Floors throughout main prep area in need of detail cleaning to remove all build up. Instructed to detail clean and maintain
Adequate ventilation & lighting; designated areas used
Mechanical ventilation in need of cleaning to remove all grease build up. Instructed to detail clean and maintain
All food employees have food handler training
All employees who no not have a city of Chicago sanitation certificate are in need of food handling certificate. Instructed to obtain and maintain
Food & non-food contact surfaces cleanable, properly designed, constructed & used
Observed inadequate stoppers for 3-compartment sink. Instructed manager to provide adequate stoppers and maintain.
Person in charge present, demonstrates knowledge, and performs duties
Observed no person in charge with valid Chicago food sanitation certificate. Instructed manager to designate person in charge during all hours of operation. Priority foundation
City of Chicago food service sanitation certificate
Observed no Chicago food sanitation manager on duty when tcs food (ground beef (147.4f) prepared and served. A Chicago food sanitation manager must be on site at all times tcs food prepared and served. Priority foundation 7-38-012 citation issued
Insects, rodents, & animals not present
Observed three live roaches crawling on 3-compartment sink, over 60 mice droppings scattered on stairway and floor in basement. Instructed manager to call an exterminator for service, clean and sanitize all areas. Priority foundation 7-38-020(a) citation issued
Insects, rodents, & animals not present
Observed numerous dead roaches inside 3-compartment sink, on floor in prep/dishwashing area and inside vanity cabinet in washroom. Instructed manager to remove all dead insects in all areas.
Contamination prevented during food preparation, storage & display
Observed candy stored on floor behind front counter. Instructed manager to elevate all food items six inches off floor.
Physical facilities installed, maintained & clean
Observed employee sleeping on floor in prep/dishwashing area. Instructed manager to provide separate area for sleeping quarters outside of prep area.
Physical facilities installed, maintained & clean
Observed excessive clutter in basement storage area. Instructed manager to remove all unnecessary articles to prevent pest harborage.
All food employees have food handler training
Observed no food handler training for employees. Any employees handling food and/or equipment must provide food handler training.
Food & non-food contact surfaces cleanable, properly designed, constructed & used
4-101.19: **c** nonfood-contact surfaces observed milk crates being used as shelving throughout the prep and storage areas. Must remove and provide shelving that is 6" off the floor and provides floor accessibility to ensure adequate facility cleaning.
Food properly labeled; original container
3-601.11: **c** standards of identity observed food storage containers without labels containing the common name of foods. Instructed to provide
Contamination prevented during food preparation, storage & display
3-307.11: **c** miscellaneous sources of contamination observed food containers stored on the floor in the walk-in cooler, prep and storage areas. Instructed manager to properly store and protect food items from contamination while stored by elevating at least six inches from the floor on raised shelving units.
Non-food/food contact surfaces clean
4-602.13: nonfood-contact surfaces of equipment shall be cleaned at a frequency necessary to preclude accumulation of soil residues. Observed an excessive amount of debris and ice buildup on the floor/walls/ceiling of the walk in freezer. Must remove excess ice, detail clean, and maintain.
Non-food/food contact surfaces clean
4-601.11(b): (b) the food-contact surfaces of cooking equipment and pans shall be kept free of encrusted grease deposits and other soil accumulations. Observed grease buildup on cooking equipment, walls, surrounding floors and shelving units in the kitchen/prep areas. Instructed to degrease, clean and sanitize.
Physical facilities installed, maintained & clean
6-501.12: **c** cleaning, frequency and restrictions observed excessive amount grease buildup, food debris, spills on the floors and surfaces throughout the facility. Dirt on floor under cooking equipment, along walls and in all corners in prep, dish washing, storage areas. Instructed manager to detail clean all floors under all equipment, floor and in all corners in all areas. Including walls in thoughout facility
Physical facilities installed, maintained & clean
6-501.13: **c** cleaning floors, dustless methods must clean debris build up from floor & drains under, around,along wall bases throughout entire facility
Physical facilities installed, maintained & clean
6-201.11: **c** floors, walls, and ceilings- cleanability observed ceilings tile panels in the prep areas encrusted in grease. Instructed to repair, replace stained/ grease encrusted ceiling tiles.
Adequate ventilation & lighting; designated areas used
6-303.11: **c** intensity- lighting noted dim lighting in walk-in freezer unit. Instructed to increase lighting intensity to ensure visibility inside unit. Must maintain
Food & non-food contact surfaces cleanable, properly designed, constructed & used
Raw wood storage shelves on site. Instd to seal same so as to be smooth, even, and easily cleanable
Insects, rodents, & animals not present
Rear overhead door not protected, approx 1/4 inch gap at sides of door. Instd to repair so as to be tight fitting and protected.
Allergen training as required
Missing allergen training for city of Chicago certified manager. Instd to obtain training and maintain verification on site
Food & non-food contact surfaces cleanable, properly designed, constructed & used
4-201.11 observed ice machine lid broken and mended in place with electrical tape. Instructed to repair to prevent contamination of food.
Contamination prevented during food preparation, storage & display
3-305.14 observed no ceiling in place over food preparation in basement. Noted food handlers actively preparing crab rangoon mix and pork on table directly underneath hanging plastic wrapping containing unknown liquid source and accumulation of dead insect carcass. Instructed to provide overhead protection and maintain protection of unpackaged food from environmental sources of contamination. Priority foundation violation. #7-38-005. Citation issued.
Non-food/food contact surfaces clean
4-602.13 observed heavy grease and food build up along grills, inside fryers, wok station, walls and piping connected to equipment throughout middle prep area. Instructed to clean and maintain in order to prevent pest harborage.
Physical facilities installed, maintained & clean
6-201.13 observed wallbase in basement prep area in disrepair, wall basing detached, cracks, and gaps. Instructed to repair and seal open holes to prevent pest entry to said area.
Adequate ventilation & lighting; designated areas used
6-501.14 observed ventilation hood equipment and grates dripping with accumulated grease buildup. Instructed to remove buildup, clean and maintain system
Food & non-food contact surfaces cleanable, properly designed, constructed & used
4-501.13: **c** microwave ovens observed the interior and exterior of the microwave not clean. Instructed to clean and maintain at all times.
Food-contact surfaces: cleaned & sanitized
4-602.11(b-e): **c** equipment food-contact surfaces and utensils-frequency observed the ice bin interior in need of cleaning. Instructed to remove ice, clean and maintain at all times.
Food properly labeled; original container
3-302.12: **c** food storage containers identified with common name of food observed food storage containers without labels containing the common name of foods. Instructed to provide.
Insects, rodents, & animals not present
6-501.112: **c** removing dead or trapped birds, insects, rodents and other pests observed in dining room, front prep storage, water heater closet, and rear prep area dead oriental roaches. Noted spider webs in mens toilet room instructed to remove dead oriental roaches, remove spider webs in toilet room clean and sanitize all said areas
Non-food/food contact surfaces clean
4-601.11(b): (b) the food-contact surfaces of cooking equipment and pans shall be kept free of encrusted grease deposits and other soil accumulations. Observed grease buildup on cooking equipment, walls, surrounding floors and shelving units in the kitchen/prep areas. Instructed to degrease, clean and sanitize.
Non-food/food contact surfaces clean
4-601.11(c): (c) nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris. Observed the interior of the reach in coolers in need of cleaning. Instructed to detail clean.
Non-food/food contact surfaces clean
4-602.13: nonfood-contact surfaces of equipment shall be cleaned at a frequency necessary to preclude accumulation of soil residues. Observed an excessive amount of debris and ice buildup on the reac-in freezer. Must remove excess ice, detail clean, and maintain.
Plumbing installed; proper backflow devices
5-205.15: **c** system maintained in good repair (in good repair) observed at 3 comp sink leaking from middle basin plumbing, instructed to repair and maintain
Physical facilities installed, maintained & clean
6-501.114: **c** maintaining premises, unnecessary items and litter observed clutter stored on floor hvac and water heater closet, and front prep side storage room. Instructed manager to remove all unused articles and equipment to prevent pest harborage.
Physical facilities installed, maintained & clean
6-501.12: **c** cleaning, frequency and restrictions observed food debris and spills on the floors and surfaces throughout the facility. Instructed to detail clean under all shelving units, interior of prep coolers, hot-holding units, prep tables and deep fryers to remove spills, food debris, dirt buildup and/or grease. Must maintain at all times.
Physical facilities installed, maintained & clean
6-501.12: **c** cleaning, frequency and restrictions must clean debris build up from floor & drains under,around,along wall bases in dry food & paper storage area,bar.
Physical facilities installed, maintained & clean
6-501.12: **c** cleaning, frequency and restrictions instructed to detail clean and maintain all cooking equipment, ingredient containers, racks and shelving with flour, dust, grease, dead insects and dirt build-up throughout. Recommended to increase cleaning frequency and maintain at all times.
Food & non-food contact surfaces cleanable, properly designed, constructed & used
4-101.19: **c** nonfood-contact surfaces observed milk crates being used as shelving throughout the prep and storage areas. Must remove and provide shelving that is 6" off the floor and provides floor accessibility to ensure adequate facility cleaning.
City of Chicago food service sanitation certificate
Noted person in charge without original city of Chicago food service manager certificate on site while preparing and handling time and temperature control for safety(tcs) foods during inspection. Informed person in charge city of Chicago original food service certificate must remain posted on site and certified manager on site during tcs food prep, cooking, serving and operating hours. Priority foundation violation #7-38-012. Citation issued.
Food properly labeled; original container
3-601.11: **c** standards of identity observed food storage containers without labels containing the common name of foods. Instructed to provide
Contamination prevented during food preparation, storage & display
3-307.11: **c** miscellaneous sources of contamination observed food containers stored on the floor in the walk-in cooler, prep and storage areas. Instructed manager to properly store and protect food items from contamination while stored by elevating at least six inches from the floor on raised shelving units.
Non-food/food contact surfaces clean
4-602.13: nonfood-contact surfaces of equipment shall be cleaned at a frequency necessary to preclude accumulation of soil residues. Observed an excessive amount of debris and ice buildup on the floor/walls/ceiling of the walk in freezer. Must remove excess ice, detail clean, and maintain.
Non-food/food contact surfaces clean
4-601.11(b): (b) the food-contact surfaces of cooking equipment and pans shall be kept free of encrusted grease deposits and other soil accumulations. Observed grease buildup on cooking equipment, walls, surrounding floors and shelving units in the kitchen/prep areas. Instructed to degrease, clean and sanitize.
Physical facilities installed, maintained & clean
6-501.12: **c** cleaning, frequency and restrictions observed excessive amount grease buildup, food debris, spills on the floors and surfaces throughout the facility. Dirt on floor under cooking equipment, along walls and in all corners in prep, dish washing, storage areas. Instructed manager to detail clean all floors under all equipment, floor and in all corners in all areas. Including walls in thoughout facility
Physical facilities installed, maintained & clean
6-501.13: **c** cleaning floors, dustless methods must clean debris build up from floor & drains under, around,along wall bases throughout entire facility
Physical facilities installed, maintained & clean
6-201.11: **c** floors, walls, and ceilings- cleanability observed ceilings tile panels in the prep areas encrusted in grease. Instructed to repair, replace stained/ grease encrusted ceiling tiles.
Adequate ventilation & lighting; designated areas used
6-303.11: **c** intensity- lighting noted dim lighting in walk-in freezer unit. Instructed to increase lighting intensity to ensure visibility inside unit. Must maintain
Previous priority foundation violation corrected
Observed previous priority foundation violations not corrected within specified time frame on the inspection report# 2646658 dated for 11/12/26 (#38)6-501.111: **pf** controlling pests (pest activity, harborage) observed pest activity with more than 25 small flies noted during inspection. Small fly activity was observed at front prep and front prep counter where slicer and signs are located. Instructed to consult pest control as additional services are needed to minimize or eliminate activity prior to re-inspection instructed person in charge that the violation shall now classified as a priority item due to previous noncompliance. Must correct before re-inspection. Priority violation #7-42-090. Citation issued.
Food & non-food contact surfaces cleanable, properly designed, constructed & used
Observed shipping plastic on exterior of ice machine. Instructed person in charge to remove and maintaint surface smooth and easily cleanable.
Plumbing installed; proper backflow devices
Observed faucet of three compartment sink repaired with non-cleanable pourous material. Instructed person in charge to repair areas with proper cleanable fixtures.
Plumbing installed; proper backflow devices
Observed handsink in rear bar area with leak at bottom of basin. Instructed person in charge to repair and maintain.
Food & non-food contact surfaces cleanable, properly designed, constructed & used
4-201.11 observed multiple cooling untis in prep area with gaskets in disrepair. Instructed to replace and maintain
Contamination prevented during food preparation, storage & display
3-307.11 observed ice scoops stored improperly in bar area on top of mats stored on equipment.instucted to provide clean container to store said scoop in in between uses
Toilet facilities: properly constructed, supplied, & cleaned
6-501.19 observed toilet room located inside prep area not self closing. Instructed to proide and maintain
Physical facilities installed, maintained & clean
6-501.12 observed floors in dry storage in need of cleaning under shelving units. Instructed to remove all dried food debris throughout said space. Instructed to clean and saniize under heavy cooking equipment in prep area and maintain
Physical facilities installed, maintained & clean
6-501.114 observed excessive clutter in basement room next to walk in cooler as well as space leading to outside receptacle area. Instructed to remove unneccesary items, organize and elevate all items at least 6 inches off floor.
Adequate ventilation & lighting; designated areas used
6-303.11 observed inadequate lighting in rear prep area during inspection. Instructed to increase and maintain
Allergen training as required
2-102.13 observed no proof of allergen certification on site during inspection. Instructed to obtain and maintain on site for review.
The newest inspections carrying this citation, with the inspector's own note.
Counted over Nov 28, 2025 to Nov 28, 2026. Inspection volume moves with the city’s own scheduling, so a rise here is not necessarily a decline in standards.